Immunocytometric quantitation of foeto-maternal haemorrhage with the Abbott Cell-Dyn CD4000 haematology analyser.

Little BH, Robson R, Roemer B, Scott CS

Queen Margaret Hospital, Branch Laboratory, Whitefield Road, Dunfermline, Fife, UK.

This study evaluated the extended use of a haematology analyser (Abbott Cell-Dyn CD4000) for the immunofluorescent enumeration of foeto-maternal haemorrhage (FMH) with fluorescein isothiocyanate-labelled monoclonal anti-RhD. Method performance was assessed with artificial FMH standards, and a series of 44 clinical samples. Within run precision was <15% (coefficient of variation, CV) for FMH volumes of 3 ml and above, 18.8% at an FMH volume of 2 ml and 31.7% at an FMH volume of 1 ml. Linearity analysis showed excellent agreement (observed FMH% = 0.98x expected FMH% + 0.02), and a close relationship (R(2) = 0.99) between observed and expected FMH percentages. The lower limit of quantification of the CD4000 (SRP-Ret) method with a maximum CV of 15% was 1.6 ml, and the limit of detection was <1 ml. Parallel Kleihauer-Betke test (KBT) assessments of FMH standards showed an overall trend for higher KBT values (observed = 1.25x expected - 0.38). At an FMH level of 4 ml, KBT observer estimates ranged from 0.57 to 11.94 ml with a mean inter-observer CV of 63%. For 44 clinical samples, there was decision point agreement between KBT and SRP-Ret results for 42 samples with an FMH of <2 ml. Analysis in the low FMH range (<1 ml) showed that small volume foetal leaks could be detected with the SRP-Ret method in most of 23 samples with negative KBT results. CD4000 SRP-Ret method performance for FMH determination was similar to that reported for flow cytometry.

Published 2 February 2005 in Clin Lab Haematol, 27(1): 21-31.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2004-2008 Anemia Research Today. All Rights Reserved.



Anemia Research Today Archive:

Volume 1 (2004)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2005)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 5 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)



Anemia Books

Raffi's Animal Rescue (Formac First Novels)

Raffi's Animal Rescue (Formac First Novels)